Author |
Message |
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 27.01.2006 - 10:22 #28797
|
|
Basic
Joined: Feb 11, 2004
Posts: 157
Location: okr. HC a PN
|
|
A este v mojom kraji :
PN : Eltec, Elos,
TT : Hagard hall, Kopun
Madunice: Masmart
Trebatice : Elko |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 27.01.2006 - 10:24 #28799
|
|
Basic
Joined: Feb 11, 2004
Posts: 157
Location: okr. HC a PN
|
|
No ja mam s i-centrom velmi dobre skusenosti, vsak bodaj by nie ked za mnou stoji velka firma. preto tam mam zlavy cca 20% az nie viac.... |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 27.01.2006 - 12:34 #28807
|
|
Basic
Joined: Máj 25, 2003
Posts: 264
|
|
Skuste priamo u vyrobcu pri objednani celeho balenia sa to urcite oplati , jedneho casu som to objednaval priamo od nich maju rozvoz po celej SR http://www.scame.sk/ |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 11:29 #28860
|
|
Basic
Joined: Dec 01, 2004
Posts: 214
Location: Bratislava
|
|
odberatelia SCAME v BA:
E.D.E.N.EL-MAT s r.o. Komárňanská 24 02/53637395
SVENT EX s r.o. Páričkova 18 02/55560034-5
VEREX ELTO s.r.o. Elektrárenská 1 02/58103111
ANMIMA Cablnkova 3, Bratislava 02/64364046
GALIK & VESELY s.r.o. Osuskeho 3, 851 03 Bratislava 02/62311880,62246924
HAGARD:HAL Ivanská cesta 34 02/43411978, 80
I-Center spol.s r.o. Stara Vajnorska 15, 831 04 Bratislava 3 02/49101626
MC elektro spol. s.r.o. Stara Vajnorska 17, 831 04 Bratislava 02/44253865-6 |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 11:37 #28861
|
|
Basic
Joined: Nov 16, 2003
Posts: 66
|
|
Ako riesite uchytenie o stlp pri scame krabiciach? |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 11:47 #28862
|
|
Basic
Joined: Dec 01, 2004
Posts: 214
Location: Bratislava
|
|
presnejsia cena krabic LUCA bez gumovych prechodiek:
LUCA 220x170x80 IP55 270 Sk Galik&Vesely aj CSAT
LUCA 310x240x110 IP55 470 Sk Galik&Vesely, CSAT je lacnejsi 440 Sk |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 11:48 #28863
|
|
Basic
Joined: Dec 01, 2004
Posts: 214
Location: Bratislava
|
|
uchytenie robievame stahovackami o vyloznik, na ktorom je antena (minimalne v 3 bodoch aby sa nekyvala..) |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 11:50 #28864
|
|
Majster
Joined: Máj 12, 2004
Posts: 4579
Location: Bratislava
|
|
rafa posli foto, takto si to clovek len tazko predstavi... |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 12:39 #28866
|
|
Basic
Joined: Dec 01, 2004
Posts: 214
Location: Bratislava
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 14:24 #28878
|
|
|
to rafa, ale aspon priechodky ste mohli pouzit, cena cca 8sk. a mas to fakt izovolane voci vode. |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 14:46 #28884
|
|
Majster
Joined: Feb 25, 2003
Posts: 2606
Location: BA,BB
|
|
andreas4all wrote: to rafa, ale aspon priechodky ste mohli pouzit, cena cca 8sk. a mas to fakt izovolane voci vode.
odspodu ti tam voda nenatecie a mam take skusenosti ze je lepsie ked tam aspon mala dierka ostane. Totizto nikdy to nezavries uplne hermeticky a nikdy to nezavries tak aby tam nebola ziadna vlhkost, ta potom kondezuje kade tade po stenach a kvapka aj na zariadenia. |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 16:18 #28891
|
|
|
tak hej, ale voda ked zacne mrznut, tak mrzne aj smerom hore... tak potom neviem ako to uzatvarete, ja nemam skusenosti s kondenzujucou vodou... |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 18:24 #28900
|
|
Majster
Joined: Máj 12, 2004
Posts: 4579
Location: Bratislava
|
|
ja pouzivam krabice s tymi gumenymi "stuplami" lem mam obavy ze casom (posobenim slnka, snehu, zimy, mrazu...) zacnu tie gumy tvrdnut a nebudu tesnit, mate s tym niekto skusenosti uz? |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 20:32 #28911
|
|
Majster
Joined: Jan 12, 2003
Posts: 4250
Location: /dev/null
|
|
andreas4all: diery zospodu neuzatvaram a s vodou v krabici som sa este nestretol... zato zopar dobre uzatvorenych som uz stretol a voda v nich bola... |
|
|
|
|
|
|
Post subject: RE: Elektroinstalacna katuža IPxx -ktoru pouzit??
Posted: 28.01.2006 - 20:55 #28912
|
|
Basic
Joined: Dec 01, 2004
Posts: 214
Location: Bratislava
|
|
jj, jednu perfektne uzavretu mal jeden zakaznik, ku ktoremu sme dosli, otvorili a radio plavalo |
|
|
|
|
|
|
Powered by PNphpBB2 © 2003-2005 The PNphpBB Group Credits |