Post subject: PON powermeter
Posted: 07.11.2015 - 17:33 #109910
|
|
Ucen
Joined: Aug 09, 2004
Posts: 753
|
|
Caute,
ma vyznam powermeter pri PON sieti? Da sa s tym nieco realne diagnostikovat? Pouzivate to niekto pri PON? |
|
|
|
|
|
|
Post subject: PON powermeter
Posted: 07.11.2015 - 19:47 #109911
|
|
Majster
Joined: Okt 21, 2003
Posts: 4247
|
|
neos wrote: ›Caute,
ma vyznam powermeter pri PON sieti? Da sa s tym nieco realne diagnostikovat? Pouzivate to niekto pri PON?
mam powermeter ktory sa zaradi do trasy, a ukazuje silu signalu z kazdej strany. zaroven funguje sluzba cez tu trasu, takze sa da vidiet, ci je signal stabilny, atd. trojkombinacia OTDR + powermeter + viditelne svetlo je na diagnostiku optickych sieti nepostradatelna. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 07.11.2015 - 19:58 #109912
|
|
Basic
Joined: Dec 07, 2012
Posts: 13
|
|
Pre technika ,ktory riesi koncove pripojky to vyznam urcite ma .Idealne Pon powermeter z viditelnym svetlom.Otdr uz ozaj ked nieco sa stane a zlyhaju meter zo svetlom. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 07.11.2015 - 20:18 #109913
|
|
Basic
Joined: Aug 14, 2011
Posts: 209
|
|
tak uz minimalne je dobre vediet u klientov aka je uroven signalu, sice tento udaj ukazuje aj ONU, ale aj pri vystavbe pon si vies rychlo preverit uroven na jednotlivych splitroch. napr. minule mi na jednom sfp module poklesol vystupny signal o 6dbm a pomocou powermetra som to hned diagnostikoval...urcite to ma vyznam |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 08.11.2015 - 19:47 #109915
|
|
Ucen
Joined: Aug 09, 2004
Posts: 753
|
|
A co hovorite na OTDR v nizsich cenovych kategoriach do 3000 EUR? Ma to nejake zasadne K.O. nevyhody oproti drahym kombajnom typu EXFO? Z pohladu diagnostiky v PON.
Narazil som na prvy problem, ked sa ONT u zakaznika nechyta. Ale cela trasa sa da presvietit lokatorom, vratane splitra, co je cca 11dB. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 09.11.2015 - 18:45 #109923
|
|
Basic
Joined: Dec 07, 2012
Posts: 13
|
|
To nespojenie onu moze mat viacej pricin.Najcastejsie nejaky makroohyb ,powermetrom nameras v pohode ,ale nejde. To byva vacsinou v kazete ,alebo u zakaznika v koncovej skatulke.Stava sa sem tam aj spinavy konektor. Pokial ides k zakaznikom vzduchom a pouzivas drop kabel ,tak pozor na kotvy. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 11.11.2015 - 10:17 #109930
|
|
Ucen
Joined: Aug 09, 2004
Posts: 753
|
|
tomdeep wrote: ›To nespojenie onu moze mat viacej pricin.Najcastejsie nejaky makroohyb ,powermetrom nameras v pohode ,ale nejde. To byva vacsinou v kazete ,alebo u zakaznika v koncovej skatulke.Stava sa sem tam aj spinavy konektor. Pokial ides k zakaznikom vzduchom a pouzivas drop kabel ,tak pozor na kotvy.
K zakaznikovi ide pigtail s konektorom zapojenym priamo do ONT. Druhu koniec je navareny v kazete. Najskor sa ten pigtail poskodil pri instalacii. Je to klasicky optokon patchcord s konektorom na jednej strane. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 26.11.2015 - 18:50 #110040
|
|
Ucen
Joined: Aug 09, 2004
Posts: 753
|
|
tomdeep wrote: ›To nespojenie onu moze mat viacej pricin.Najcastejsie nejaky makroohyb ,powermetrom nameras v pohode ,ale nejde. To byva vacsinou v kazete ,alebo u zakaznika v koncovej skatulke.Stava sa sem tam aj spinavy konektor. Pokial ides k zakaznikom vzduchom a pouzivas drop kabel ,tak pozor na kotvy.
Takze odpoviem si sam. Mozno to niekomu do buducna pomoze. Chyba bola v ostrych ohyboch, signal na konci -45dBm . Po vyrovnani -16,5 |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 29.11.2015 - 23:31 #110059
|
|
Majster
Joined: Feb 14, 2011
Posts: 2544
|
|
To akože ostrý ohyb = pokles signalu? Alebo ostrý ohyb = zlomene vlakno = pokles signalu? |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 29.11.2015 - 23:34 #110060
|
|
Majster
Joined: Okt 21, 2003
Posts: 4247
|
|
samozrejme ze ostry ohyb = utlm... nedavno som bol diagnostikovat chybu, vlakna islo presvietit viditelnym svetlom, ale link sa nechytil na 300 metrov ani s 3km SFPckami.. zavada sa nasla OTDRkom, buffer v spojke bol 2x tesne omotany okolo stredoveho tahoveho prvku v kabli, po narovnani buffra link bez problemov... |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 30.11.2015 - 01:06 #110062
|
|
Majster
Joined: Feb 14, 2011
Posts: 2544
|
|
studirujem tie ohyby podla nejakych dokumentov ktore som nasiel je to cca
Makro-ohybové straty (10x15 mm polomer, 1550nm) 0,25 dB
(1x10 mm polomer, 1550nm) 1,0 dB
to mi pride troška zanedbatelne nie? či toto je teoria a prax je tak 25db? |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 30.11.2015 - 03:16 #110064
|
|
Majster
Joined: Okt 21, 2003
Posts: 4247
|
|
utlm pri ohybe zavisi od vlakna, su rozne druhy, maju rozne znacenie, kazde znesie iny ohyb. vo vseobecnosti sa da poveadt, ze dnes je mozne vyrabat ovela odolnejsie vlakna ako volakedy. niektore mozes ohybat pomerne brutalne a utlm skoro ziadny, niektore ohnes trochu a uz je zle.
z praxe, v jednej kazete mam z jedneho starsieho kabla (asi 10rocneho) vlakna slucku s polomerom asi 2 cm (priemer slucky 4 cm) a jej utlm je ak si dobre pamatam 4,5 dB, takze to ma hodne daleko od toho co si napisal vyssie. |
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 16.12.2015 - 18:52 #110253
|
|
Basic
Joined: Aug 14, 2011
Posts: 209
|
|
|
|
|
|
Post subject: RE: PON powermeter
Posted: 16.12.2015 - 23:56 #110259
|
|
Majster
Joined: Okt 21, 2003
Posts: 4247
|
|
xtome2 wrote: ›a tento zazrak uz niekto skusal? mozno by sa to hodilo ako nahrada miesto miesto OTDR
na jednoduchu diagnostiku mozno staci, ale ja by som nechcel OTDR ktore ukazuje iba vzdialenosti, graf je graf... |
|
|
|
|
|
|